Ebay and Paypal no longer sends us your email address. To receive the free generic instruction you must send your email address. IF YOU ORDER FROM THIS AUCTION MAKE SURE TO TELL US WHAT INSTRUMENT THE BACKLIGHT IS FOR SO WE CAN SEND YOU THE CORRECT ONE SHIPPING NOW INCLUDES TRACKING YOU MIGHT FIND A CHEAPER BACKLIGHT BUT YOU WON'T FIND A BETTER BACKLIGHT MADE IN THE US A SEE FULL LIST OF INSTRUMENTS WITH REPLACEABLE BACKLIGHTS BELOW WE NO LONGER ACCEPT INTERNATIONAL ORDERS THROUGH US BASED FREIGHT FORWARDERS International customers must call or email us directly (info below) ******************************************************************** Ya NO ACEPTAMOS ÓRDENES INTERNACIONALES A TRAVÉS DE LOS TRANSPORTADORES Los clientes internacionales deben llamar o enviarnos un correo electrónico directamente (información a continuación) IF YOU DON'T SEE YOUR INSTRUMENT AT THIS AUCTION CHECK OUR OTHER AUCTIONS THIS AUCTION IS FOR BACKLIGHTS THAT FIT INSIDE OF THE LCD DISPLAYS OF THE INSTRUMENTS LISTED BELOW AKAI: ASQ10 ( ASQ-10 ) , CD3000series (
CD-3000 ), MPC3000 ( MPC-3000
), MPC60 ( MPC-60 ), MPC60 II ( MPC-60 II ), S1000 series ( S-1000 ),
S1100 (S-1100 ), S3000 series ( S-3000 ),
S3200 (S-3200 ), S900 ( S-900 ), S950 (S-950 ), VX600 ( VX-600 ) CASIO: CZ-1 ( CZ-1 ), FZ1 ( FZ-1 ), FZ10 ( FZ-10 ), VZ1 ( VZ-1 ), VZ10M ( VZ10-M ) DIGITAL MUSIC: MX8 (MX-8 ) DYNACORD: ADD1 ( ADD-1 ) ELKA: MK76 ( MK-76 ) EMU: Darwin , E4 ( E-4 ), EIV (E-IV ), E64 ( E-64 ), E6400 ( E-6400 ), Esynth (
E-synth ), EMULATOR II & II+ , E-III (all versions) , EMAX ,
EMAX II (all versions), ESI32 ( ESI-32 ), SP1200 ( SP-1200 ) HOG LIGHTING CONTROLLERS: HOG 2 wing , HOG 500 , HOG 1000 HOHNER: HS1 ( HS-1 ), Hs1m ( HS-1M ) KAWAI: K5 ( K-5 ), K5m ( K-5m ), K5000 ( K-5000 ) KORG: A1
( A-1 ), A2 ( A-2 ), A3 ( A-3 ), DSS1 ( DSS-1 ), DS8 ( DS-8 ), i1 ( i-1 ),
i2 ( i-2 ), i3 ( i-3 ), O1r/w (O1RW ), O1 W , 01 W ( 01W , O1w ), O1/W-FD ( O1WFD ),
O1/W-pro ( O1Wpro ), N264 ( N-264 ), N364 ( N-364 ), RE1 ( RE-1 ), SDD3300 ( SDD-3300 ), T1 ( T-1 ), T2 (
T-2 ), T3 ( T-3 ), Wavestation , Wavestation EX ( Wavestation-EX
), Wavestation AD ( Wavestation-AD ), X2 ( X-2 ), X3 ( X-3 ), X3r ( X-3r ) KURZWEIL: K2000 ( K-2000 ), K2VX (K-2VX ), K2000r ( K-2000r ) LEXICON: MRC LINN: 9000 PEAVEY: AUTOGRAPH, C8p, MULTIFEX ROLAND: A50 (A-50 ), A80 ( A-80 ), D550 (D-550 ),D70 ( D-70 ),DJ70
(DJ-70 ), DJ70 MK II ( DJ-70
MK II ) E660 ( E-660 ),
G800 ( G-800 ), GC8 ( GC-8 ), Juno2 ( Juno-2 ), Juno1
( Juno-1),
JW50 ( JW-50 ), MC500 (MC-500 ),
MC 500 MK II ( MC-500 MK II ) MKS20 (
MKS-20 ), MKS80 ( MKS-80), MV30 ( MV-30),
PG1000 ( PG-1000 ), S10 ( S-10 ), S770
(S-770 ), S750 ( S-750 ), SP700 (SP-700 ), VK1000 (
VK-1000 ), W30 (W-30 ) SAMICK: SXP501 ( SXP-501 ) SEQUENTIAL CIRCUITS: PROPHET VS ( PROPHET-VS ) STUDER: A727 (A-727 ) T C ELECTRONICS : tc 1128 (tc-1128 ) YAMAHA: DX1
( DX-1 ), DX5 ( DX-5 ), SY77 ( SY-77 ), SY99 (SY-99 ), TG77 (TG-77 ),
REV7 ( REV-7 ), W5 (W-5 ), W7 ( W-7 ), QS300 ( QS-300 ). DO NOT PRY APART YOUR DISPLAY. DAMAGE MAY RESULT!! CONTACT US IF YOU HAVE ANY QUESTIONS OR DO NOT SEE YOUR INSTRUMENT ON THE LIST CONTACT INFORMATION IS LISTED BELOW. Our backlights have the contacts in the correct position for your display. No messy jumpers needed.There is minor soldering involved. Most people consider this a repair they can do themselves. You can also take your instrument to a service center and have them do it. We
ship to all worldwide locations serviced by the US post office.
Shipping charges vary on international destinations. Ask for freight
charges when ordering. We also include an email of the contents of a CD that is free with a backlight order. The
email is a generic explanation of what to do once the display has been removed from the
instrument. Your instrument may be different than what is shown but the principle is the same. Again, DO NOT pry apart your display as damage may occur. The email is
helpful when working on Korg, Akai, and other displays. ALL INFORMATION
ABOUT TOOLS IS ON THE email. LEGAL
NOTICE: WE WILL NOT BE HELD RESPONSIBLE FOR ANY LOSS/ DAMAGE OR INJURY
RESULTING FROM THE INSTALLATION OF REPLACEMENT BACKLIGHTS. IF YOU ARE IN
ANY DOUBT AS TO YOUR ABILITY TO INSTALL THEM PLEASE REFER INSTALLATION
TO SUITABLY QUALIFIED PERSONNEL. WHILE EVERY EFFORT IS MADE TO ENSURE
THAT THIS INFORMATION IS CORRECT,WE CAN NOT BE HELD RESPONSIBLE FOR
LOSS/DAMAGE OR INJURY RESULTING FROM ANY ERRORS CONTAINED WITHIN THIS
INFORMATION. You
will most likely need a new backlight but make sure the inverter is
working. An easy test is turn the instrument on in a very dark room. If
there is even a slight glow the inverter is good. If there is no glow it
could be the inverter or just a totally dead backlight. If the light is
completely dead you need to check the inverter either at the backlight
contact points or at the inverter voltage output pins to see if there is
power going to the backlight (approx. 70-100vac @ 400hz). If there is
power you only need a new backlight. If there is no power you need to
fix the inverter circuit and it is very likely that you also need a new
backlight. If you don't have proper test equipment you can order and
install a new backlight (which you most likely need anyway) and if that
doesn't fix it you will need to hunt down the problem in the inverter
circuit.
Returns Accepted for this item if it's within 14 Days